11 research outputs found
Recommended from our members
Leaf-inspired microcontact printing vascular patterns.
The vascularization of tissue grafts is critical for maintaining viability of the cells within a transplanted graft. A number of strategies are currently being investigated including very promising microfluidics systems. Here, we explored the potential for generating a vasculature-patterned endothelial cells that could be integrated into distinct layers between sheets of primary cells. Bioinspired from the leaf veins, we generated a reverse mold with a fractal vascular-branching pattern that models the unique spatial arrangement over multiple length scales that precisely mimic branching vasculature. By coating the reverse mold with 50 μg ml-1 of fibronectin and stamping enabled selective adhesion of the human umbilical vein endothelial cells (HUVECs) to the patterned adhesive matrix, we show that a vascular-branching pattern can be transferred by microcontact printing. Moreover, this pattern can be maintained and transferred to a 3D hydrogel matrix and remains stable for up to 4 d. After 4 d, HUVECs can be observed migrating and sprouting into Matrigel. These printed vascular branching patterns, especially after transfer to 3D hydrogels, provide a viable alternative strategy to the prevascularization of complex tissues
Recommended from our members
Flexible shrink-induced high surface area electrodes for electrochemiluminescent sensing
Photolithographically defined metallic thin film on commodity shrink-wrap is leveraged to create robust electrodes. By thermally shrinking the film, electrodes are reduced by 20x in footprint for improved resolution and conductivity with >600% enhancements in electrochemically active surface area; as electrochemiluminescent sensors, they demonstrate improved limits of detection
Recommended from our members
Leaf-inspired microcontact printing vascular patterns.
The vascularization of tissue grafts is critical for maintaining viability of the cells within a transplanted graft. A number of strategies are currently being investigated including very promising microfluidics systems. Here, we explored the potential for generating a vasculature-patterned endothelial cells that could be integrated into distinct layers between sheets of primary cells. Bioinspired from the leaf veins, we generated a reverse mold with a fractal vascular-branching pattern that models the unique spatial arrangement over multiple length scales that precisely mimic branching vasculature. By coating the reverse mold with 50 μg ml-1 of fibronectin and stamping enabled selective adhesion of the human umbilical vein endothelial cells (HUVECs) to the patterned adhesive matrix, we show that a vascular-branching pattern can be transferred by microcontact printing. Moreover, this pattern can be maintained and transferred to a 3D hydrogel matrix and remains stable for up to 4 d. After 4 d, HUVECs can be observed migrating and sprouting into Matrigel. These printed vascular branching patterns, especially after transfer to 3D hydrogels, provide a viable alternative strategy to the prevascularization of complex tissues
Shrink-film microfluidic education modules: Complete devices within minutes
As advances in microfluidics continue to make contributions to diagnostics and life sciences, broader awareness of this expanding field becomes necessary. By leveraging low-cost microfabrication techniques that require no capital equipment or infrastructure, simple, accessible, and effective educational modules can be made available for a broad range of educational needs from middle school demonstrations to college laboratory classes. These modules demonstrate key microfluidic concepts such as diffusion and separation as well as “laboratory on-chip” applications including chemical reactions and biological assays. These modules are intended to provide an interdisciplinary hands-on experience, including chip design, fabrication of functional devices, and experiments at the microscale. Consequently, students will be able to conceptualize physics at small scales, gain experience in computer-aided design and microfabrication, and perform experiments—all in the context of addressing real-world challenges by making their own lab-on-chip devices
Recommended from our members
Tunable shrink-induced honeycomb microwell arrays for uniform embryoid bodies.
Embryoid body (EB) formation closely recapitulates early embryonic development with respect to lineage commitment. Because it is greatly affected by cell-cell and cell-substrate interactions, the ability to control the initial number of cells in the aggregates and to provide an appropriate substrate are crucial parameters for uniform EB formation. Here we report of an ultra-rapid fabrication and culture method utilizing a laser-jet printer to generate closely arrayed honeycomb microwells of tunable sizes for the induction of uniform EBs from single cell suspension. By printing various microwell patterns onto pre-stressed polystyrene sheets, and through heat induced shrinking, high aspect micromolds are generated. Notably, we achieve rounded bottom polydimethylsiloxane (PDMS) wells not easily achievable with standard microfabrication methods, but critical to achieve spherical EBs. Furthermore, by simply controlling the size of the microwells and the concentration of the cell suspension we can control the initial size of the cell aggregate, thus influencing lineage commitment. In addition, these microwells are easily adaptable and scalable to most standard well plates and easily integrated into commercial liquid handling systems to provide an inexpensive and easy high throughput compound screening platform
Recommended from our members
Skin-mountable stretch sensor for wearable health monitoring
This work presents a wrinkled Platinum (wPt) strain sensor with tunable strain sensitivity for applications in wearable health monitoring. These stretchable sensors show a dynamic range of up to 185% strain and gauge factor (GF) of 42. This is believed to be the highest reported GF of any metal thin film strain sensor over a physiologically relevant dynamic range to date. Importantly, sensitivity and dynamic range are tunable to the application by adjusting wPt film thickness. Performance is reliable over 1000 cycles with low hysteresis after sensor conditioning. The possibility of using such a sensor for real-time respiratory monitoring by measuring chest wall displacement and correlating with lung volume is demonstrated